Can anyone phone call me if a cutler hammer CH breaker will fit right into a siemens panel??? If not what other breaker will work? thanks
*

Can anyone tell me if a cutler hammer CH breaker will fit right into a siemens panel??? If no what various other breaker will work? thanks
Different jurisdictions have different rules concerning the breakers come be supplied in business upgrades. Some desire the exact same name brand in service upgrades if others room okay with any type of breaker the the right type.As ns recall, Cutler Hammer BR, Homeline, and GE work-related in a Siemans, yet I recommend you usage Siemans.
*

Different jurisdictions have different rules concerning the breakers to be supplied in business upgrades. Some want the same name brand in service upgrades if others room okay with any breaker the the appropriate type.
What perform you typical by "same surname brand in service upgrades"? If you have an currently C-H panel, you have the right to only upgrade to one more C-H?
*

The Cutler-Hammer "CL" breakers room classified for use in a Siemens panel. :blink:I don"t think any of them room "listed" other than the Siemens brand itself.
I"d need to say there is a large difference between service panels and the breakers used in company panels. What i wrote method some jurisdictions desire GE breakers in a brand-new GE panel; Siemens breakers in a new Siemens panel; QO breakers in a brand-new Square D panel; and Homeline breakers in a brand-new Homeline panel.Others don"t care.At any type of rate, a Cutler-Hammer CH breaker won"t work in a Siemens.
*

The Murray breakers are 100% identical, and probably roll off the same assembly line. I"ve drilled personally a Muray and a Siemens breaker, and also they"re part-for-part exactly the same. BUT> Murray breakers are not rated because that in a Siemens panel. The Cutler Hammer form CL (not CH) is the only one on the industry right now that is rated to walk in the Siemens panel, as much as i know, besides a Siemens breaker. If memory serves, the short-lived T&B breaker line was additionally rated for use in the Siemens panels.
One factor not to provide DIY advice:Catch a man a fish and also you have the right to sell it come him.Teach a man to fish and you�ve destroyed a great business opportunity.
*

At one point I think top top this very forum there was a snapshot of a murray arc fault breaker in a siemens box directly from the factory.
Can anyone phone call me if a cutler hammer CH breaker will fit into a siemens panel??? If not what various other breaker will work? thanks
I should install a breaker in the interim in a 3 phase siemens panel and also I don"t have finish info on the panel. What i do have actually is a grainy picture that i took v a cabinet phone. What I have to do is download a 2 pole breaker to feeding a short-lived power distro. I"ve got a 50A twin CH breaker the fits many panels i encounter. Deserve to anyone do out sufficient from the picture to assist direct me? thanks
It"s difficult to tell, yet that looks like a bolt-on panelboard. If the is the case, then no other brand the breaker must "fit" other than for the Siemens.
It"s difficult to tell, yet that looks choose a bolt-on panelboard. If the is the case, climate no other brand of breaker must "fit" other than for the Siemens.
I stopped by a Siemens distributor and told him it was a "P1" panel and he called me the didn"t tell the what he required to know. The pulled out a Cutler Hammer snap in breaker and also said that it to be a cheap breaker that might fit. I currently had the very same breaker in my kit so ns didn"t take it. Since its a 3 step panel i had concerns that that would require a unique breaker. I"ve invested some time at the Siemens site trying to discover documentation. There is a sea of info that has been an overwhelming to go through. I guess I need to get the finish numbers turn off the panel and shot to contact Siemens. Thanks.
It"s difficult to tell, however that looks prefer a bolt-on panelboard. If the is the case, climate no other brand the breaker must "fit" except for the Siemens.
I agree definetly a bolt on, and a 2-pole 50 for the is expensive, plus girlfriend probobly won"t uncover it at large box, most likely you need to discover a neighborhood siemens distributor.
Have you opened up this panel and also looked in ~ it? If you go back to the distributor and ask for a 2 pole 50 amp bolt ~ above breaker it must fit.
Have you opened up this panel and looked in ~ it? If girlfriend go back to the distributor and also ask for a 2 pole 50 amp bolt on breaker it need to fit.
I didn"t take the cover off when I to be there. However it looked to me choose a simple snap-in affair. And also I take it a picture that i thought included the information I required but afterwards I discovered that that wasn"t detailed enough come make the end all the numbers. What I deserve to make out is: P1C3??L125C?S. The distributor made that sound like there were so countless different kinds the there was little chance that we might figure that out. Ns unfortunately can"t get back to this dashboard till the job I have to use it. Thanks
Call somebody at the building and ask castle to review the brand on an currently breaker or ~ above the sticker. Ns can"t do it out on my screen.If it"s a QP, it"s a plug in. If it"s a B something, it"s a bolt on.

See more: Do You Wax The Bottom Of A Skimboard Wax Vs, Skimboard Wax Vs


I stopped by a Siemens distributor and also told him it to be a "P1" panel and also he called me the didn"t tell that what he required to know.
I sure hope you discover a better distributor 보다 that in you area.:laughing:The P1 panel uses bolt-on breakers, therefore the Siemens 50A 2-pole breaker would certainly be a B250, a 3-pole would certainly be a B350.
A forum community committed to skilled electricians, contractors, and apprentices for residential and commercial work. Come join the discussion around trade knowledge, tools, certifications, wiring, builds, scales, reviews, accessories, classifieds, and also more!
General electrical DiscussionBusiness, Marketing, and SalesTools, tools and new ProductsResidential electrical ForumNEC code Forum